BPFHH - H SIMULANT TEST BOTTLE

  • MSDS: BPFHH
  • Manufacturer: CHEMTRONICS INC
  • Product Name: H SIMULANT TEST BOTTLE
  • National Stock Number: 6910-01-043-2090
Product Identification

Product ID:H SIMULANT TEST BOTTLE
MSDS Date:04/01/1986
FSC:6910
NIIN:01-043-2090
Kit Part:Y
MSDS Number: BPFHH

Responsible Party
CHEMTRONICS INC
180 OLD BEE TREE RD
SWANNANOA, NC 28778-3409
US

Emergency Phone: 704-298-7941

Info Phone: 704-298-7941

Cage: 60737

Contractor
CHEMTRONICS INC
SWANNANOA, NC 28778-3409 US

Telephone: NOT LISTED IN PHONE DIRECTORY

Cage: 60737

Ingredients

ISO-AMYL SALICYLATE

CAS: 87-20-7

RTECS: VO4375000

OSHA PEL NOT KNOWN

ACGIH TLV: NOT KNOWN

Hazards

LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NO ADVERSE EFFECTS HAVE BEEN FOUND.A 10%
SOLUTION PRODUCED NO SENSITIZATION IN HUMANS.APPROVED FOR FOOD USE
BY USFDA.
Medical Cond Aggravated by Exposure:NOT KNOWN

First Aid

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. SKIN:WASH WITH SOAP AND WATER. INGESTION:GIVE TWO GLASSES
OF WATER.INDUCE VOMITING. INHALATION:MOVE TO FRESH AIR.CALL A
PHYSICIAN FOR IN GESTION AND INHALATION.

Fire Fighting

Flash Point Method:CC
Flash Point:414F,212C
Lower Limits:NOT KNOWN
Upper Limits:NOT KNOWN
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
AND FULL TURNOUT GEAR .
Unusual Fire/Explosion Hazard:NONE KNOWN

Accidental Release

Spill Release Procedures:ABSORB WITH SAND OR VERMICULITE.PLACE IN
CLOSED CONTAINER FOR DISPOSAL.
Neutralizing Agent:NOT KNOWN

Handling

Handling and Storage Precautions:STORE IN A COOL,DRY PLACE AWAY FROM
SOURCES OF FLAME AND SPARK.
Other Precautions:NOT KNOWN

Exposure Controls

Respiratory Protection:NONE NEEDED IN WELL-VENTILATED AREA.
Ventilation:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE TO DETERMINE
IF LOCAL EXHAUST VENTILATION IS NEEDED .
Protective Gloves:WEAR RUBBER GLOVES.
Eye Protection:WEAR SPLASH-PROOF GOGGLES.
Other Protective Equipment:NOT KNOWN
Work Hygienic Practices:NOT KNOWN
Supplemental Safety and Health
NONE KNOWN

Chemical Properties

HCC:F6
Boiling Pt:B.P. Text:531F,277C
Melt/Freeze Pt:M.P/F.P Text:NOT KNOWN
Decomp Temp:Decomp Text:NOT KNOWN
Vapor Pres:NOT KNOWN
Vapor Density:>1 (AIR=1)
Spec Gravity:1.050 (WATER=1)
Evaporation Rate & Reference:>1 (N-BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS TO PALE YELLOW WITH ORCHARD SCENT.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS,OXIDIZERS,IRON CAUSES DISCOLORATION.
Stability Condition to Avoid:NOT KNOWN
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE,AND LOCAL REGULATIONS.COORDINATE WITH SUPPORTING
INSTALLATION AND/OR MACOM ENVIRONMENTAL OFFICE PRIOR TO DISPOSAL .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.